Gas detector with digital output

  • The gas detector measures the selected gas concentration
  • The gas detector is part of the digital KIMESSA CANline BUS-Network which is designed for up to 128 gas detectors and alarming units
  • linearized and temperature-compensated digital CANline BUS output signal
  • 16…30 VDC supply voltage (4-wire cable)
  • various gas sensor technologies available (electrochemical, Infrared, pellistor, semiconductor)
  • factory calibration with calibration certificate to the specified measuring range
  • Zero & Span potentiometers and calibration jack socket accessible from outside without opening the gas detector enclosure
  • water- and dust-proof IP 65 enclosure
  • rust-proof and acid-resitant steel enclosure
  • Swiss-Made
GasFormulaProductMeasuring rangeMeasurement principleDatasheet
AcetyleneC2H2KSIM 21000-100 % LELInfra red
AcetyleneC2H2KSPC 1800-100 % LELPellistor
AmmoniaNH3KSEC 5170-100/250/500/1000 ppmElectrochemical
AmmoniaNH3KSEC 517 TK0-1000 ppmElectrochemical
AmmoniaNH3KSPC 1410-1,5/3,0 Vol %Pellistor
Arsenic HydrogenAsH3KSEC 7670-1 ppmElectrochemical
Butane (R600a)C4H10KSPC 1800-100 % LELPellistor
Carbon Dioxide (R744)CO2KSIM 10900-5000 ppm/ 0-1/2.5/5/10/20 Vol %Infra red
Carbon MonoxideCOKSEC 5040-250 ppmElectrochemical
Carbon Monoxide/ Nitric Dioxide (combined)CO/NO2KSEM 504/684CO: 0-300 ppm/ NO2:0-10 ppmElectrochemical
Carbon MonoxideCOKSEC 5070-100/300/500/1000 ppmElectrochemical
ChlorineCl2KSEC 6570-5/10/20/50 ppmElectrochemical
Chlorine dioxideClO2KSEC 6470-5/10/20/50 ppmElectrochemical
DiboraneB2H6KSEC 7770-1 ppmElectrochemical
EthyleneC2H5OHKSPC 1800-100 % LEL/ 0-5000 ppmPellistor
Ethylene (Ethene)C2H4KSPC 1800-100 % LELPellistor
Ethylene OxideC2H4OKSEC 7470-30/100/1000 ppmElectrochemical
FluorineF2KSEC 7970-1/-3/-10 ppmElectrochemical
HexaneC6H14KSPC 1800-100 % LELPellistor
HydrogenH2KSEC 3070-2000 ppm/ 0-1/4 Vol %Electrochemical
HydrogenH2KSPC 1800-100 % LELPellistor
Hydrogen ChlorideHClKSEC 7070-30/100 ppmElectrochemical
Hydrogen CyanideHCNKSEC 6670-10/30/100 ppmElectrochemical
Hydrogen FluorideHFKSEC 7370-10 ppmElectrochemical
Hydrogen PeroxideH2O2KSEC 7870-100/200 ppmElectrochemical
Hydrogen SulfideH2SKSEC 6270-30/50/100/200 ppmElectrochemical
IsobutaneC4H10KSPC 1210-100 % LELPellistor
LPG (Liquefied Petroleum)C3H8/ C4H10KSIM 21000-100 % LELInfra red
LPG (Liquefied Petroleum)C3H8/ C4H10KSPC 1800-100 % LELPellistor
MethaneCH4KSIM 21000-100 % LELInfra red
MethaneCH4KSPC 1800-100 % LELPellistor
MethanolCH3OHKSIM 21000-100 % LELInfra red
MethanolCH3OHKSPC 1800-100 % LELPellistor
Nitrogen DioxideNO2KSEC 6840-10/-20/-50/-100 ppmElectrochemical
Nitrogen MonoxidNOKSEC 6770-20/-50/-100/-500 ppmElectrochemical
Nitrous OxideN2OGSIM 15700-1000/2000 ppmInfra red
OxygenO2KSEC 4070-25 Vol %Electrochemical
OzoneO3KSEC 8470-1/5 ppmElectrochemical
PentaneC5H12KSIM 21000-100 % LELInfra red
PentaneC5H12KSPC 1800-100 % LELPellistor
PhosgeneCOCl2KSEC 7570-1/3 ppmElectrochemical
PhosphinePH3KSEC 7270-5/-10/-20 ppmElectrochemical
PropaneC3H8KSIM 21000-100 % LELInfra red
PropaneC3H8KSPC 1800-3000 ppm/ 0-100 % LELPellistor
Refrigerant R134a (Tetrafluoroethane)R134aKSIM 25300-5000 ppmInfra red
Refrigerant R143a (Trifluoroethane)R143aKSIM 25300-5000 ppmInfra red
Refrigerant R404a (is R125, R143a, R134a)R404aKSIM 25300-5000 ppmInfra red
Refrigerant R410a (is R32, R125)R410aKSIM 25300-5000 ppmInfra red
RefrigerantR407C (is R32, R125, R134a)R407cKSIM 25300-5000 ppmInfra red
SilaneSiH4KSEC 7170-20/-50 ppmElectrochemical
SolventsKSIM 21000-100 % LELInfra red
SolventsKSPC 1800-100 % LELPellistor
Sulfur DioxideSO2KSEC 6370-10/-50/-100 ppmElectrochemical
Sulfur HexafluorideSF6KSIM 12600-1000/5000 ppm/ 0-5 Vol %Infra red